This section addresses the most common issues related to lighting and chromotherapy systems installed in saunas on board yachts. Marine saunas are equipped with components specifically designed for high temperatures and humid environments. Although these are premium-quality products, they may still be subject to wear, faults, or malfunctions, making regular and careful maintenance essential.
Below you will find a series of technical checks and recommended corrective actions. Our team is always available to provide technical support or to carry out onboard interventions when required.
Possible Causes and Checks to Perform
If the sauna lighting or chromotherapy system is not functioning correctly, several factors may be involved. The following points should be carefully inspected:
1. LED Driver Not Suitable for High Temperatures
Many installations use standard LED drivers that are not designed to withstand temperatures of 70–90°C (158–194°F).
• Ensure the driver is not installed inside the sauna cabin.
• Check for signs of overheating, burning, or physical deformation.
2. Lighting Fixtures Not Certified for Sauna Use
Lamps or LED strips not designed for high-temperature environments may darken, discolor, or fail prematurely.
• Verify that LEDs and light fixtures are certified for at least 125°C (257°F).
3. Electrical Cables Damaged by Heat
Prolonged exposure to heat can dry out and harden cable insulation, leading to short circuits or signal loss.
• Inspect wiring carefully, especially in areas close to the heater.
4. Oxidation of Electrical Connections
Residual condensation may penetrate electrical connections and impair system performance.
• Check the junction box and inspect terminals for signs of oxidation or corrosion.
5. Burnt or Faulty RGB / Chromotherapy Controller
Controllers not designed for high-temperature environments may freeze, fail, or become physically damaged.
• Test the controller and verify its operational integrity.
6. Unstable Onboard Power Supply
Voltage fluctuations or power surges can damage LED drivers, transformers, and control units.
• Check the stability of the yacht’s onboard electrical power supply.
How to Identify a Fault
A malfunction of the lighting or chromotherapy system is likely if one or more of the following symptoms occur:
- Lights completely off.
- Intermittent operation.
- Some chromotherapy colors not working.
- Unintended or random color changes.
- LEDs becoming dim after a few minutes of operation.
Key Checks to Identify the Root Cause
In summary, ensure that:
- The LED driver is installed outside the hot zone, in a well-ventilated area.
- Lighting fixtures are sauna-specific, certified for 125°C (257°F), with IP65/IP67 protection.
- Electrical cables, especially near the heater, are in good condition.
- The junction box is positioned outside the sauna cabin.
- No oxidation is present on electrical connections.
- The chromotherapy controller is functioning correctly.
Recommended Solutions
To restore proper operation of the sauna lighting and chromotherapy system on board a yacht, we recommend:
- Replacing LED drivers and lighting fixtures with models certified for high temperatures.
- Relocating the driver outside the sauna cabin, in a ventilated area.
- Rewiring using high-temperature silicone cables.
- Installing lighting fixtures certified IP65/IP67 and resistant up to 125°C (257°F).
- Replacing the chromotherapy controller if blocked or malfunctioning.
- Installing a stabilized power supply to protect the system from electrical surges.
Contact Centro Italia Yachting for Dedicated Support
For technical assistance with saunas and steam rooms on board yachts, please contact Centro Italia Yachting at the Italy Toll-Free Number 800 931 931, or internationally at +39 327 612 0605. Our specialized technicians are ready to provide tailored technical support and professional onboard service based on the specific issue identified.